Even when a building’s primary structure performs as intended in an earthquake, non-structural elements such as ducts, ceilings and services can move or fail. This can put people at risk, damage building systems and delay reoccupation
Seismic restraint for non-structural building elements
Motovated designs seismic restraint for non-structural building elements. We work with architects, consultants and contractors to develop practical, coordinated designs for the project.
Seismic restraint design
Design restraint for ceilings, partitions, building services and other non-structural elements.
Coordinated services
Coordinate HVAC, fire, hydraulic and electrical restraint to help manage clashes and installation.
Construction support
Construction monitoring and support with site issues, as agreed for the project.
Specialist seismic restraint experience
Motovated has seven Chartered Professional Engineers across the team, including two CPEng in its dedicated seismic restraint team. The specialists bring 30 years’ combined experience in this field.
Engineering design for building elements
Non-structural elements and their connections need to be designed and detailed for the earthquake actions and movement demands relevant to each project.
We can design for one service or coordinate restraint across several elements to help manage interfaces and installation practicality.
- Suspended ceilings and partitions
- HVAC and mechanical services
- Fire sprinkler systems
- Hydraulic pipework and electrical systems
- Service coordination and installation practicality
- ULS, SLS1 and SLS2 requirements, where applicable
Design, review and construction support
PS1 · Design
Design documentation for the agreed project scope.
PS2 · Design review
Independent review of design prepared by another engineer, where appropriate to the project.
PS4 · Construction review
Construction review based on the monitoring undertaken and project requirements.
Motovated can support projects from initial design through to construction monitoring. The producer statement and scope depend on the work undertaken and relevant Building Consent Authority requirements.
Standards and engineering approach
Our engineers consider NZS 1170.5, NZS 4219, AS/NZS 2785:2020 and other standards relevant to the building element and project scope.
AS/NZS 2785:2020 covers suspended ceiling design and installation; seismic actions need to be addressed separately in the engineering design. Where a specific standard does not apply, our engineers use first-principles design to develop a project-specific solution.
The applicable standards and editions depend on the project and should be confirmed with the project engineer.
Customer Stories
Services
From our blog
Let’s talk about your seismic project